Skip to content

Test Data Library

Hours from different salt spray standards are not directly comparable. See how to read them →

Published test results by system
SystemTestResultStandardSource
PG-S1Neutral salt spray≥ 2,000 h, no red rustPASSGB/T 10125-2021Supplier data sheet
PG-S1Acetic acid salt spray≥ 800 hPASSGB/T 10125-2021Supplier data sheet
PG-S1Copper-accelerated salt spray≥ 350 hPASSGB/T 10125-2021Supplier data sheet
PG-S1Heat-transfer efficiency loss≤ 1.8%PASSGB/T 8446.2Supplier data sheet
PG-S1Adhesion (cross-cut)Grade 0PASSGB/T 9286Supplier data sheet
PG-S1Pencil hardness≥ 2HPASSGB/T 6739Supplier data sheet
PG-S1Thermal cycling−60 °C to 150 °C × 100 cycles, no crackingPASSGB/T 2423.4Supplier data sheet
PG-S12% H₂SO₄ and 2% NaOH immersion48 h, no changePASS—Supplier data sheet
PG-WNeutral salt spray800 h, rating ≥ 9.5PASSGB/T 1771-2007Supplier data sheet
PG-WAdhesion (cross-cut)Grade 0PASS—Supplier data sheet

How to read this table

Each row gives the system, the test, the result, the standard and the source. A result applies to the conditions of that test — its substrate, film thickness and failure criterion — and should only be compared with results measured the same way.

Test equipment

Equipment in the partner laboratory used for coating tests.

Where do the results come from?

They are quoted from the coating data sheets, with the standard each test was run to. Ask us for the data sheet of the system you are considering.

Can I get a test run on my own coil?

Yes. Salt spray and heat-transfer tests on your coil geometry can be arranged; new salt spray tests take several weeks.

Request a quote

Tell us the equipment, the site and the destination port. We reply within 24 hours.

WhatsAppRequest a Quote