Test Data Library
Hours from different salt spray standards are not directly comparable. See how to read them →
| System | Test | Result | Standard | Source |
|---|---|---|---|---|
| PG-S1 | Neutral salt spray | ≥ 2,000 h, no red rustPASS | GB/T 10125-2021 | Supplier data sheet |
| PG-S1 | Acetic acid salt spray | ≥ 800 hPASS | GB/T 10125-2021 | Supplier data sheet |
| PG-S1 | Copper-accelerated salt spray | ≥ 350 hPASS | GB/T 10125-2021 | Supplier data sheet |
| PG-S1 | Heat-transfer efficiency loss | ≤ 1.8%PASS | GB/T 8446.2 | Supplier data sheet |
| PG-S1 | Adhesion (cross-cut) | Grade 0PASS | GB/T 9286 | Supplier data sheet |
| PG-S1 | Pencil hardness | ≥ 2HPASS | GB/T 6739 | Supplier data sheet |
| PG-S1 | Thermal cycling | −60 °C to 150 °C × 100 cycles, no crackingPASS | GB/T 2423.4 | Supplier data sheet |
| PG-S1 | 2% H₂SO₄ and 2% NaOH immersion | 48 h, no changePASS | — | Supplier data sheet |
| PG-W | Neutral salt spray | 800 h, rating ≥ 9.5PASS | GB/T 1771-2007 | Supplier data sheet |
| PG-W | Adhesion (cross-cut) | Grade 0PASS | — | Supplier data sheet |
How to read this table
Each row gives the system, the test, the result, the standard and the source. A result applies to the conditions of that test — its substrate, film thickness and failure criterion — and should only be compared with results measured the same way.
Test equipment
Equipment in the partner laboratory used for coating tests.

UV accelerated weathering chamber 
Acid and alkali immersion tank for chemical resistance tests 
Outdoor natural weathering rack with coated samples 
Reciprocating abrasion tester 
Pencil hardness tester 
Bend tester for film flexibility
Related
- CoatingsWaterborne Polysiloxane (Sol-Gel) Coil Coating
- StandardsASTM B117 Neutral Salt Spray: What the Hours Mean
- GuidesHow to Verify a Supplier's Salt Spray Claims
- CoatingsBaked Polysiloxane-Urethane Clearcoat
- StandardsHow Coating Impact on Heat Transfer Is Tested
- CoatingsWaterborne Two-Component Coil Coatings
Also see
Where do the results come from?
They are quoted from the coating data sheets, with the standard each test was run to. Ask us for the data sheet of the system you are considering.
Can I get a test run on my own coil?
Yes. Salt spray and heat-transfer tests on your coil geometry can be arranged; new salt spray tests take several weeks.
Request a quote
Tell us the equipment, the site and the destination port. We reply within 24 hours.