Coil Coating Materials Supply

Pack sizes and shelf life
| System | Pack sizes | Shelf life | Shipping |
|---|---|---|---|
| PG-S1 | 25 kg drums | 12 months | General cargo; protect from freezing |
| PG-S2 | 0.95 kg, 20 kg, 180 kg | at least 6 months | Per its SDS |
| PG-W | 125 kg drums | Stated with the quote | Waterborne; protect from freezing |
| PG-C | Stated with the quote | 24 months | Solvent-based; expected to ship as dangerous goods |
Values are from the coating data sheets.
What comes with every supply
The English technical data sheet, the safety data sheet and an application guide covering surface preparation, mixing, film thickness and cure. Two-component systems include mixing ratios and pot life — PG-W must be used within 8 hours of mixing.
Process
01Specify
Equipment, exposure, destination
02Sample
First-article coating for new systems
03Inspect
Incoming check with photo record
04Coat & cure
Dip, spray or flood; cure logged
05QC
Film thickness, coverage, fin bridging, adhesion
06Report & ship
Batch report travels with the goods
Coating options
Selected by site corrosivity. Salt-spray hours from different standards are not compared across systems.
| System | Film thickness | Cure | Best for |
|---|---|---|---|
| PG-S1 Waterborne polysiloxane (sol-gel) | 5–15 μm | Thermal or ambient | New coils before shipment, OEM dip lines |
| PG-S2 Polysiloxane-urethane clearcoat | 5–10 μm | 160 °C / 60 min | Aluminium radiators, bakeable heat exchangers |
| PG-W Waterborne two-component | 5–10 g/m² per side | 80 °C touch-dry | Coil lines, mild coastal and humid sites |
| PG-C Air-dry two-component, chemical-resistant | 20–40 μm | Ambient 72 h | Complete units, chemical and wastewater sites |
Related
- CoatingsWaterborne Polysiloxane (Sol-Gel) Coil Coating
- ServiceCoil Coating Repair Kits for Field Application
- GuidesAre Waterborne Coil Coatings Dangerous Goods for Shipping?
- CoatingsWaterborne Two-Component Coil Coatings
- GuidesShelf Life and Storage of Coil Coatings in Hot Climates
- CoatingsAir-Dry Two-Component Chemical-Resistant Coating
Also see
Is there a minimum order?
Minimum quantities depend on the system and pack size and are confirmed with the quote.
Which system ships as general cargo?
PG-S1 is listed as general cargo on its data sheet and must be kept from freezing. PG-C is solvent-based and is expected to ship as dangerous goods.